Open Access Open Access  Restricted Access Subscription or Fee Access

Advantages of Use of Base Isolator and Fluid Viscous Dampers

Dhanesh Shrikhande, Girish Joshi

Abstract


Several disastrous earthquakes have struck the world in recent decades, resulting in increasing human
deaths due to building collapse and significant structural damage The damages due to seismic actions
have made us realise that structures (residential, industrial, bridges etc) must be designed and
constructed to be resistant to earthquake. The building which are not designed properly will be prone
to major damage. The prime option to withstand these building during severe earthquakes is seismic
improvement. There are multiple options available for seismic improvement of the building. The base
isolation technique and energy dissipation approach, on the other hand, are the most popular seismic
protection techniques. Seismic base isolation technology with use of various isolators energy disipiation
techniques (fuid viscous damper) are being used to minimize the seismic response of structure as
compared to structure with rigid base. Similarly, energy dissipation techniques like Dampers are widely
used. The techniques of base isolator and fluid viscous damper help to lessen the seismic response of a
structure when compared to a fixed base construction.


Keywords: Base isolator, viscous dampers, disastrous earthquakes, building collapse, seismic actions


Full Text:

PDF

References


R. V. Vajreshwari Umachagi, Katta Venkataramana, G. R. Reddy, “Applications of Dampers for

Vibration Control of Structures: an Overview,” Int. J. Res. Eng. Technol., vol. 02, no. 13, pp. 6–11,

, doi: 10.15623/ijret.2013.0213002.

A. M. G. Arya, Alice T.V, “Seismic Analysis of High Damping Rubber Bearings for Base

Isolation,” Int. J. Res. Eng. Technol., vol. 04, no. 01, pp. 321–327, 2015, doi:

15623/ijret.2015.0401048.

S. D. Raghunandan M H, “Seismic Pounding Between Adjacent Rc Buildings With and Without

Base Isolation System,” Int. J. Res. Eng. Technol., vol. 04, no. 06, pp. 367–375, 2015, doi:

15623/ijret.2015.0406062.

G. S. H. Vinodkumar Parma, “Advances in Control, Chemical Engineering, Civil Engineering and

Mechanical Engineering - European Conference of Chemical Engineering, ECCE’10, European

Conference of Civil Engineering, ECCIE’10, European Conference of Mechanical Engineering,

ECME’10, Eur,” Eur. Conf. Chem. Eng. ECCE’10, Eur. Conf. Civ. Eng. ECCIE’10, Eur. Conf.

Mech. Eng. ECME’10, Eur. Conf. Control. ECC’10, pp. 2319–2322, 2010.

A. K. Sonali Anilduke, “Comparision of Building for Sesmic Response By Using Base Isolation,”

Int. J. Res. Eng. Technol., vol. 04, no. 06, pp. 237–241, 2015, doi: 10.15623/ijret.2015.0406039.

S. N. Swathirani.K.S, Muralidhara.G.B, “Eatrhquake Response of Reinforced Cocrete Multi Storey

Building With Base Isolation,” Int. J. Res. Eng. Technol., vol. 04, no. 10, pp. 158–167, 2015, doi:

15623/ijret.2015.0410028.

M. W. A. H. Okine Michael Nii Sarbah, Zhao Jianchang, “Seismic Base Isolation in Strengthening

an Existing Retrofitted Masonry-Reinforced Concrete Building in Huating - China,” Int. J. Res.

Eng. Technol., vol. 04, no. 10, pp. 168–175, 2015, doi: 10.15623/ijret.2015.0410029.

S. H. Ju, C. C. Yuantien, and W. K. Hsieh, “Study of lead rubber bearings for vibration reduction

in high-tech factories,” Appl. Sci., vol. 10, no. 4, 2020, doi: 10.3390/app10041502.

H. N. Shankarling S Mandewali, “Performance Evaluation of Lead Rubber Isolators Under Seismic

Loads,” Int. J. Res. Eng. Technol., vol. 05, no. 26, pp. 21–24, 2016, doi:

15623/ijret.2016.0526005.

M. A. Baig, M. I. Khan, and M. Amir Baig, “Seismic Analysis of Fixed Base and Base Isolated

Building Using Lead Rubber Bearing Pushover Analysis of Steel Frame View projectBenchmarking of Indian Seismic CODE IS1893:2016 View project Seismic Analysis of Fixed Base

and Base Isolated Building Using ,” vol. 5, no. August, 2018, [Online]. Available:

https://www.researchgate.net/publication/327271116

W. A. Al-Kutti and A. B. M. S. Islam, “Potential design of seismic vulnerable buildings

incorporating lead rubber bearing,” Buildings, vol. 9, no. 2, 2019, doi: 10.3390/buildings9020037.

P. S. Gitanjali Sahu, “Comparative Analysis of Effects of Base Isolator & Fluid Viscous Damper

on Response of A RCC Structure Gitanjali,” Int. J. Res. Eng. Technol., vol. 06, no. 11/Nov201,

S. K. Sahu, “Seismic Response of Asymmetric Reinforced Concrete Structure with Lead Rubber

Bearing,” vol. 7, no. 6, pp. 30–36, 2020.